SciCombinator

Discover the most talked about and latest scientific content & concepts.

Concept: Ophthalmology

434

Myopia is a common cause of vision loss, with uncorrected myopia the leading cause of distance vision impairment globally. Individual studies show variations in the prevalence of myopia and high myopia between regions and ethnic groups, and there continues to be uncertainty regarding increasing prevalence of myopia.

Concepts: Ophthalmology, Myopia, Visual impairment, Anarchism

423

Zika virus (ZIKV) is an emerging flavivirus that causes congenital abnormalities and Guillain-Barré syndrome. ZIKV infection also results in severe eye disease characterized by optic neuritis, chorioretinal atrophy, and blindness in newborns and conjunctivitis and uveitis in adults. We evaluated ZIKV infection of the eye by using recently developed mouse models of pathogenesis. ZIKV-inoculated mice developed conjunctivitis, panuveitis, and infection of the cornea, iris, optic nerve, and ganglion and bipolar cells in the retina. This phenotype was independent of the entry receptors Axl or Mertk, given that Axl(-/-), Mertk(-/-), and Axl(-/-)Mertk(-/-) double knockout mice sustained levels of infection similar to those of control animals. We also detected abundant viral RNA in tears, suggesting that virus might be secreted from lacrimal glands or shed from the cornea. This model provides a foundation for studying ZIKV-induced ocular disease, defining mechanisms of viral persistence, and developing therapeutic approaches for viral infections of the eye.

Concepts: Immune system, Gene, Virus, Infection, Eye, Ophthalmology, Tears, Optic nerve

175

The purpose of this study was to evaluate the visual outcome of chronic occupational exposure to a mixture of organic solvents by measuring color discrimination, achromatic contrast sensitivity and visual fields in a group of gas station workers. We tested 25 workers (20 males) and 25 controls with no history of chronic exposure to solvents (10 males). All participants had normal ophthalmologic exams. Subjects had worked in gas stations on an average of 9.6 ± 6.2 years. Color vision was evaluated with the Lanthony D15d and Cambridge Colour Test (CCT). Visual field assessment consisted of white-on-white 24-2 automatic perimetry (Humphrey II-750i). Contrast sensitivity was measured for sinusoidal gratings of 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 and 20.0 cycles per degree (cpd). Results from both groups were compared using the Mann-Whitney U test. The number of errors in the D15d was higher for workers relative to controls (p<0.01). Their CCT color discrimination thresholds were elevated compared to the control group along the protan, deutan and tritan confusion axes (p<0.01), and their ellipse area and ellipticity were higher (p<0.01). Genetic analysis of subjects with very elevated color discrimination thresholds excluded congenital causes for the visual losses. Automated perimetry thresholds showed elevation in the 9°, 15° and 21° of eccentricity (p<0.01) and in MD and PSD indexes (p<0.01). Contrast sensitivity losses were found for all spatial frequencies measured (p<0.01) except for 0.5 cpd. Significant correlation was found between previous working years and deutan axis thresholds (rho = 0.59; p<0.05), indexes of the Lanthony D15d (rho=0.52; p<0.05), perimetry results in the fovea (rho= -0.51; p<0.05) and at 3, 9 and 15 degrees of eccentricity (rho= -0.46; p<0.05). Extensive and diffuse visual changes were found, suggesting that specific occupational limits should be created.

Concepts: Mann–Whitney U, Non-parametric statistics, Vision, Visual perception, Visual system, Ophthalmology, Visual field, Ellipse

172

Small incision lenticule extraction or SMILE is a novel form of ‘flapless’ corneal refractive surgery that was adapted from refractive lenticule extraction (ReLEx). SMILE uses only one femtosecond laser to complete the refractive surgery, potentially reducing surgical time, side effects, and cost. If successful, SMILE could potentially replace the current, widely practiced laser in-situ keratomileusis or LASIK. The aim of this study is to evaluate whether SMILE is non-inferior to LASIK in terms of refractive outcomes at 3 months post-operatively.

Concepts: Surgery, Laser, Cornea, Ophthalmology, The Current, Refractive surgery, LASIK, Laser surgery

171

BACKGROUND: Uveitis is an autoimmune disease of the eye that refers to any of a number of intraocular inflammatory conditions. Because it is a rare disease, uveitis is often overlooked, and the possible associations between uveitis and extra-ocular disease manifestations are not well known. The aim of this study was to characterise uveitis in a large sample of patients and to evaluate the relationship between uveitis and systemic diseases. METHODS: The present study is a cross-sectional study of a cohort of patients with uveitis. Records from consecutive uveitis patients who were seen by the Uveitis Service in the Department of Ophthalmology at the Medical University of Vienna between 1995 and 2009 were selected from the clinical databases. The cases were classified according to the Standardization of Uveitis Nomenclature Study Group criteria for uveitis. RESULTS: Data were available for 2619 patients, of whom 59.9% suffered from anterior, 14.8% from intermediate, 18.3% from posterior and 7.0% from panuveitis. 37.2% of all cases showed an association between uveitis and extra-organ diseases; diseases with primarily arthritic manifestations were seen in 10.1% of all cases, non-infectious systemic diseases (i.e., Behcet’s disease, sarcoidosis or multiple sclerosis) in 8.4% and infectious uveitis in 18.7%. 49.4% of subjects suffering from anterior uveitis tested positively for the HLA-B27 antigen. In posterior uveitis cases 29% were caused by ocular toxoplasmosis and 17.7% by multifocal choroiditis. CONCLUSION: Ophthalmologists, rheumatologists, infectiologists, neurologists and general practitioners should be familiar with the differential diagnosis of uveitis. A better interdisciplinary approach could help in tailoring of the work-up, earlier diagnosis of co-existing diseases and management of uveitis patients.

Concepts: Medicine, Epidemiology, Medical terms, Infection, Rheumatoid arthritis, Ophthalmology, Ankylosing spondylitis, Uveitis

171

This systematic review gives an overview of foveal crowding (the inability to recognize objects due to surrounding nearby contours in foveal vision) and possible interventions. Foveal crowding can have a major effect on reading rate and deciphering small pieces of information from busy visual scenes. Three specific groups experience more foveal crowding than adults with normal vision (NV): 1) children with NV, 2) visually impaired (VI) children and adults and 3) children with cerebral visual impairment (CVI). The extent and magnitude of foveal crowding as well as interventions aimed at reducing crowding were investigated in this review. The twofold goal of this review is : [A] to compare foveal crowding in children with NV, VI children and adults and CVI children and [B] to compare interventions to reduce crowding.

Concepts: Enzyme, Perception, Ophthalmology, Learning, Disability, Visual impairment, Foveal, Cortical visual impairment

170

169

Improving adherence to manage elevated intraocular pressure (IOP) remains an unmet need. A topical bimatoprost ocular insert was compared with twice-daily timolol eye drops in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT) treated for 6 months.

Concepts: Randomized controlled trial, Intraocular pressure, Glaucoma, Ophthalmology, Trabecular meshwork, Ocular hypertension, Dorzolamide

168

We present an overview of currently available toric intraocular lenses (IOLs) and multifocal toric IOLs. Relevant patient selection criteria, IOL calculation issues, and surgical techniques for IOL implantation are discussed. Clinical outcomes including uncorrected visual acuity, residual refractive astigmatism, and spectacle independency, which have been reported for both toric IOLs and multifocal toric IOLs, are reviewed. The incidence of misalignment, the most important complication of toric IOLs, is determined. Finally, future developments in the field of toric IOLs are discussed. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.

Concepts: Ophthalmology, Lens, Presbyopia, Contact lens, Refractive error, Intraocular lens, Cataract, Toric lens

168

BACKGROUND/PURPOSE: Light-chain deposition disease (LCDD) is a rare condition characterised by deposition of monoclonal immunoglobulin light chains (LCs) in tissues, resulting in varying degrees of organ dysfunction. This study reports the characteristic clinical ocular findings seen in advanced LCDD upon development of ocular fundus changes. This is the first report to describe this entity in vivo in a series of patients. METHODS: A case series of ocular fundus changes in three patients with kidney biopsy-proven LCDD. All patients underwent best corrected visual acuity (BCVA) exam, perimetry, colour fundus photography and fluorescein angiography; two patients underwent indocyanine green angiography, optical coherence tomography, ultrasound and electroretinography; and one patient underwent fundus autofluorescence. RESULTS: Three patients, 53-60 years old at initial presentation, were studied. All three presented with night blindness, poor dark adaptation, metamorphopsia and visual loss. Examination revealed serous and serohaemorrhagic detachments, multiple retinal pigment epithelial (RPE) tears, diffuse RPE degeneration and progressive fibrotic changes. Neither choroidal neovascularisation nor other vascular abnormalities were present. Final best corrected visual acuity (BCVA) ranged from 20/40 to 20/300. CONCLUSIONS: Progressive LC deposition in the fundus seems to damage RPE pump function with flow disturbance between choroid and retina. This pathogenesis can explain the evolution to RPE detachments and subsequent rips and progressive retinal malfunction.

Concepts: Immune system, Retina, Eye, Ophthalmology, Retinitis pigmentosa, Immunoglobulin light chain, Fluorescein angiography, Fundus camera